7866+7872D H₂ Purity Analyzer

Wide Range • Temperature Compensation • Explosion-proof Sensor • Auto-drain


Measurement Range: (0~100)% CO₂ in AIR; (0~100)% H₂ in CO₂; (75~100)% H₂ in AIR

Accuracy: ±2% F.S (for standard binary gas mixtures)

Response Time: H₂: 63%: 13s; 90%: 23s; CO₂: 63%: 24s; 90%: 45s

  • +86 400-659-6699
  • Contact Now
Sticky Navigation Example

Product Introduction 

The 7866+7872D utilizes Honeywell's thermal conductivity sensors for precise binary gas analysis, specifically designed for generator H₂ purity monitoring during gas replacement processes in power plants.

Key Features 

1.Generator manufacturer-specified product.

2.Wide-range temperature compensation & explosion-proof sensor.

3.Precision sampling system for field calibration.

4.Proprietary auto-drain & safety bypass.

Technical Specifications 


Parameter

Value

Measurement Range

(0~100)% CO₂ in AIR;(0~100)% H₂ in CO₂

(75~100)% H₂ in AIR

Accuracy

±2% F.S (for standard mixed gases)

Response Time

H₂:63% in 13s;90% in 23s

CO₂:63% in 24s;90% in 45s

Output Range

(4~20) mA (factory default)

Corresponds to (75~100)% H₂ in AIR, max load 800Ω

Sample Flow Rate

0.5 SCFH (1 SCFH ≈ 500 ml/min)

Explosion-proof Rating

Ex d ⅡC T6

Dimensions

800×400×1660 mm (L×W×H)

Weight

131 kg

Sticky Navigation Example

Product Introduction 

The 7866+7872D utilizes Honeywell's thermal conductivity sensors for precise binary gas analysis, specifically designed for generator H₂ purity monitoring during gas replacement processes in power plants.

Key Features 

1.Generator manufacturer-specified product.

2.Wide-range temperature compensation & explosion-proof sensor.

3.Precision sampling system for field calibration.

4.Proprietary auto-drain & safety bypass.

Technical Specifications 


Parameter

Value

Measurement Range

(0~100)% CO₂ in AIR;(0~100)% H₂ in CO₂

(75~100)% H₂ in AIR

Accuracy

±2% F.S (for standard mixed gases)

Response Time

H₂:63% in 13s;90% in 23s

CO₂:63% in 24s;90% in 45s

Output Range

(4~20) mA (factory default)

Corresponds to (75~100)% H₂ in AIR, max load 800Ω

Sample Flow Rate

0.5 SCFH (1 SCFH ≈ 500 ml/min)

Explosion-proof Rating

Ex d ⅡC T6

Dimensions

800×400×1660 mm (L×W×H)

Weight

131 kg

图片展示

 Phone:+86 400 659 6699

 E-mail:info@relations.com.cn

 Address:No.101 Yulan Street, High-tech Industrial Development Zone, Zhengzhou, Henan Province, China

Henan Relations Co., Ltd.  Copyright © 2021 all rights reserved

Products

分类标题

News

分类标题

About

分类标题

Contact

分类标题

Contact Us

+86 400 659 6699

Henan Relations Co., Ltd.

Phone:+86 152 0371 5596

E-mail:info@relations.com.cn

Address:No.101 Yulan Street, High-tech Industrial Development Zone, Zhengzhou, Henan Province, China

Henan Relations Co., Ltd.  Copyright ©  2021 All rights reserved

Technical Support:ShanHou  

Hello! Welcome to inquire~
Contacts
Phone
400 659 6699/0371-67996699
Working Time
Monday to Friday
E-mail
info@relations.com.cn
Qrcode
Qrcode
业务微信二维码
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了